RCBO Type B 2Pole 10KA 30mA 50Hz 40A 63A EKL5-63 Circuit Breaker
Typ B RCBO 2POLIG 10KA 30mA 50Hz 40A 63A EKL5-63 Circuit Breaker
RCBO vom Typ B , in addition to normal AC, can detect high frequency AC and pure DC earth leakage currents. Reducing the risk of fire and or electrocution through automatic disconnection of the electrical supply relies on the selection of the correct type of RCBO EKL5-63 B ab.
Elektrische Eigenschaften
Modell | EKL5-63 |
Typ (Wellenform der erfassten Erdleckage) | B Typ RCBO |
Nennstrom In | 16A, 20A, 25A, 32A, 40A, 50A, 63A |
Stangen | 2Pole und 4Pole |
Nennspannung Ue | 2-polig: 230 V / 240 V, 4-polig: 400 V / 415 V. |
Isolationsspannung Ui | 500V |
Nennfrequenz | 50/60 Hz |
Bemessungsrestbetriebsstrom (I n) | 30 mA, 100 mA, 300 mA |
Bewertetes Restherstellungs- und Bruchvermögen (I m) | 500 (In = 2540 A) 630 (In = 63 A) |
Kurzschlussstrom Inc = I c | 10000A |
SCPD-Sicherung | 10000 |
Pausenzeit unter I n | ≤ 0,1 s |
Nennimpulsfestigkeit (1,5 / 50) Uimp | 4000V |
Dielektrische Prüfspannung bei ind.Freq. für 1min | 2,5 kV |
Elektrische Lebensdauer | 2.000 Zyklen |
Mechanische Lebensdauer | 4.000 Zyklen |
Installation
Kontaktpositionsanzeige | Ja |
Schutzgrad | IP20 |
Umgebungstemperatur (mit Tagesdurchschnitt ≤ 35 ° C) | -5 ° C ~ + 40 ° C. |
Lagertemperatur | -25 ° C ~ + 70 ° C. |
Anschlussart des Terminals | Kabel- / Stiftsammelschiene / U-Sammelschiene |
Klemmengröße oben / unten für Kabel | 25 mm 2 18-3AWG |
Klemmengröße oben / unten für Sammelschiene | 25 mm 2 18-3AWG |
Anzugsmoment | 2,5 Nm 22 In-lbs |
Montage | Auf DIN-Schiene EN60715 (35mm) mittels Schnellclip-Vorrichtung |
Verbindung | Von oben und unten |
Gesamt- und Einbaumaß (mm)
Anwendung
EV & PV - Anlagen
Frequenzumrichter
USV - Anlagen
Hochfrequenz - Leistungswandler
Baustromversorgung Gebäude Schränke
EKL1-63 Typ B RCDs können sinusförmigen Wechselstrom, pulsierenden Gleichstrom, Verbund aus Mehrfrequenz- und glatten Gleichstrom-Restströmen erkennen. Außerdem werden Auslösebedingungen mit unterschiedlichen Frequenzen von 50 Hz bis 1 kHz definiert. In einem elektrischen Wechselstromverteilungsnetz kann ein reiner Gleichstrom-Reststrom hauptsächlich von dreiphasigen Gleichrichterschaltungen, aber auch von bestimmten einphasigen Gleichrichtern erzeugt werden. MIDA-80B Typ B RCD sind für Lasten mit dreiphasigem Gleichrichter vorgesehen wie Frequenzumrichter, PV-Anlage, EV-Ladestation und medizinische Geräte.
Function
Type B RCBO Circuit Breaker Control electric circuits.
Protect people against indirect contacts and additionalprotection against direct contacts.
Protect installations against fire hazard due to insulation faults.Residual current circuit breakers are used in housing, tertiarysector and industry Selection Detectable wave form
B class Tripping is ensured for sinusoidal AC residual currents pulsed DCresidual currents,
alternatingresidual sinusoidal currents up to1000Hz, pulsating direct residual EKL5-63B
currents and for smooth directresidual currents, whether applied suddenly or increasing slowly.
Tripping sensitivity 30mA -additional protection against direct contact EKL5-63B.
Tripping time Instantaneous,It ensures instantaneous tripping (without time- delay).
Konstruktion und Ausstattung
Elegantes Aussehen; Abdeckung und Griff in Bogenform sorgen für eine komfortable Bedienung.
Fenster zur Anzeige der Kontaktposition
Transparente Abdeckung zum Tragen des Etiketts.
Im Falle einer Überlastung zum Schutz des Stromkreises löst der FI-Schutzschalter aus und bleibt in der zentralen Position, was eine schnelle Lösung der fehlerhaften Leitung ermöglicht. Der Griff kann bei manueller Bedienung nicht in dieser Position bleiben. Bietet Schutz gegen Erdschluss / Leckstrom und Funktion der Isolation.
Hohe Kurzschlussstromfestigkeit EKL5-63B Gilt
Anwendbar für
Ausgestattet mit fingergeschützten Anschlussklemmen. EKL5-63B Fehlerstromschutzschalter
Feuerfeste Kunststoffteile halten einer abnormalen Erwärmung und starken Stößen stand.
Trennen Sie den Stromkreis automatisch, wenn er geerdet ist Fehler- / Leckstrom tritt auf und überschreitet die Nennempfindlichkeit. Unabhängig von Stromversorgung und Netzspannung und frei von externen Störungen Spannungsschwankungen EKL1-63B einpoliger FI-Schutzschalter mit zwei Strompfaden; zweipoliger FI-Schutzschalter; dreipoliger FI-Schutzschalter; dreipoliger FI-Schutzschalter mit vier Strompfaden, vierpoliger FI-Schutzschalter